Measurement Specialties PCI-2513 Guía de usuario

Busca en linea o descarga Guía de usuario para No Measurement Specialties PCI-2513. Measurement Specialties PCI-2513 User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2 - PCI-2513

PCI-2513 User's Guide Installing the PCI-2513 10 3. To test your installation and configure your board, run the InstaCal utility installed in

Pagina 3 - HM PCI-2513.doc

PCI-2513 User's Guide Installing the PCI-2513 11 Connector pinout 16-channel single-ended mode pinout (8-channel differential signals in parent

Pagina 4 - Table of Contents

PCI-2513 User's Guide Installing the PCI-2513 12 68341 353416835 Figure 2. CA-68-3S and CA-68-6S cable Field wiring and signal termination You

Pagina 5 - Chapter 5

13 Chapter 3 Functional Details This chapter contains detailed information on all of the features available from the board, including:  a block dia

Pagina 6 - About this User's Guide

PCI-2513 User's Guide Functional Details 14 Digital input channel sampling is not done during the "dead time" of the scan period wher

Pagina 7 - Introducing the PCI-2513

PCI-2513 User's Guide Functional Details 15 Figure 4. Analog channel scan of voltage inputs example Digital I/O Twenty-four TTL-level digital

Pagina 8 - Installing the PCI-2513

PCI-2513 User's Guide Functional Details 16 A note on the hardware analog level trigger and comparator change state When analog input voltage

Pagina 9 - Installing the software

PCI-2513 User's Guide Functional Details 17 Set pre-trigger > 0 when using counter as trigger source When using a counter for a trigger sour

Pagina 10 - Configuring the hardware

PCI-2513 User's Guide Functional Details 18 When reading synchronously, all counters are set to zero at the start of an acquisition. When readi

Pagina 11 - Cabling

PCI-2513 User's Guide Functional Details 19 Stop at the top mode The counter stops at the top of its count. The top of the count is FFFF hex (6

Pagina 12 - Installing multiple boards

PCI-2513 User's Guide Document Revision 6, December, 2010 © Copyright 2010, Measurement Computing Corporation

Pagina 13 - Functional Details

PCI-2513 User's Guide Functional Details 20 Figure 6. Debounce model block diagram Trigger after stable mode In the trigger after stable mode

Pagina 14 - Analog input

PCI-2513 User's Guide Functional Details 21 The following time periods (T1 through T6) pertain to the above drawing.  T1 – In the illustrated

Pagina 15 - Triggering

PCI-2513 User's Guide Functional Details 22 Figure 10.Optimal debounce time for trigger before stable mode Trigger after stable mode behaves

Pagina 16 - Digital triggering

PCI-2513 User's Guide Functional Details 23 Quadrature encoders generally have three outputs: A, B, and Z. The A and B signals are pulse trains

Pagina 17 - Counter inputs

PCI-2513 User's Guide Functional Details 24 Maximizing encoder accuracy If there are 512 pulses on A, the encoder position is accurate to with

Pagina 18 - Counter modes

PCI-2513 User's Guide Functional Details 25 The "A" signal must be connected to an even-numbered channel and the associated "B&q

Pagina 19 - Debounce modes

PCI-2513 User's Guide Functional Details 26 Figure 15. Two encoders connected to pins on the SCSI connector* * Connections can instead be made

Pagina 20

PCI-2513 User's Guide Functional Details 27 Example: Timer outputs Timer outputs are programmable square waves. The period of the square wave c

Pagina 21

PCI-2513 User's Guide Functional Details 28 A channel's detect signal shows a rising edge and is True (1) when the channel's data mee

Pagina 22 - Encoder mode

PCI-2513 User's Guide Functional Details 29 Detection setpoints act on 16-bit data only. Since the PCI-2513 has 32-bit counters, data is return

Pagina 23

3 HM PCI-2513.doc Your new Measurement Computing product comes with a fantastic extra — Management committed to your satisfaction! Thank you for choo

Pagina 24

PCI-2513 User's Guide Functional Details 30 Using the setpoint status register You can use the setpoint status register to check the current st

Pagina 25

PCI-2513 User's Guide Functional Details 31 You can program control outputs programmed on each setpoint, and use the detection for channel 4 to

Pagina 26 - Encoder #2

PCI-2513 User's Guide Functional Details 32 Figure 20. Channel 3 in hysteresis mode Detecting setpoints on a totalizing counter In the follo

Pagina 27 - Example: Timer outputs

PCI-2513 User's Guide Functional Details 33 In hysteresis mode, each setpoint has two forced update values. Each update value can drive one tim

Pagina 28

PCI-2513 User's Guide Functional Details 34 When setting a detection window, keep a scan period in mind. This applies to analog inputs and coun

Pagina 29 - Setpoint configuration

35 Chapter 4 Calibrating the PCI-2513 Every range of a PCI-2513 device is calibrated at the factory using a digital NIST traceable calibration method

Pagina 30 - Examples of control outputs

36 Chapter 5 Specifications All specifications are subject to change without notice. Typical for 25 °C unless otherwise specified. Specifications in

Pagina 31

PCI-2513 User's Guide Specifications 37 Note 2: Noise reflects 10,000 samples at 1 MHz, typical, differential short, using CA-68-3S cable. Di

Pagina 32 - Detection setpoint details

PCI-2513 User's Guide Specifications 38 Input sequencer Analog, digital, and counter inputs can be scanned based on either an internal programm

Pagina 33 - FIRSTPORTC

PCI-2513 User's Guide Specifications 39 Trigger sources and modes Table 7. Trigger sources and modes Input scan trigger sources  Single chann

Pagina 34

4 Table of Contents Preface About this User's Guide ...

Pagina 35 - Calibrating the PCI-2513

PCI-2513 User's Guide Specifications 40 Mechanical Table 11. Mechanical specifications Vibration MIL STD 810E cat 1 and 10 Dimensions 165 mm (W

Pagina 36 - Specifications

PCI-2513 User's Guide Specifications 41 Table 14. 8-channel differential pinout Pin Function Pin Function 68 ACH0 HI 34 ACH0 LO 67 AGND 33 ACH1

Pagina 37 - Counters

Declaration of Conformity Manufacturer: Measurement Computing Corporation Address: 10 Commerce Way Suite 1008 Norton, MA 02766 USA Category

Pagina 38 - Frequency/pulse generators

Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: [email protected]

Pagina 39 - Environmental

PCI-2513 User's Guide 5 Using detection setpoints for output control ...

Pagina 40 - Main connector and pinout

6 Preface About this User's Guide What you will learn from this user's guide This user's guide explains how to install, configure, and

Pagina 41 - 5 V output, up to 500 mA

7 Chapter 1 Introducing the PCI-2513 Overview: PCI-2513 features The PCI-2513 is supported under popular Microsoft® Windows® operating systems. The

Pagina 42 - Declaration of Conformity

8 Chapter 2 Installing the PCI-2513 What comes with your PCI-2513 shipment? As you unpack your PCI-2513, verify that the following components are inc

Pagina 43

PCI-2513 User's Guide Installing the PCI-2513 9 Additional documentation In addition to this hardware user's guide, you should also receiv

Comentarios a estos manuales

Sin comentarios